Can Furman m-8x handle electrical load?

To many ads? Support ODJT and see no ads!

djoutlaw

New DJ
Jun 17, 2008
225
0
I have a Furman M-8x and use it to power 2 cd players, mixer, and one amp--sometimes a portable light for the mixer.

Since I'm not a electronic guru, I would like to know if I connect a few more items will the Furman handle the electrical load or do I need something else?

Here is what I will be connecting to the Furman:
2 cd players, mixer, portable light, crossover, 2 amps--will the Furman work or shut down?
 
I have a Furman M-8x and use it to power 2 cd players, mixer, and one amp--sometimes a portable light for the mixer.

Since I'm not a electronic guru, I would like to know if I connect a few more items will the Furman handle the electrical load or do I need something else?

Here is what I will be connecting to the Furman:
2 cd players, mixer, portable light, crossover, 2 amps--will the Furman work or shut down?

Each one of those Conditioners have a Power rating in AMPS. Add the total individual load of the gear you want to use and as long as it does not exceed to power rating of the Furman you should be OK
 
Good amps should not have a problem running directly from the wall. I would just run the CD players, mixer, processing, etc. from the Furman and the amps from the wall.

I've been able to run 2 RMX 2450's from a single 15 AMP circuit. However when you push them hard they may need more power than what's available so I just made my circuits 20 AMPS to be on the safe side.
 
Get a Kill-a-Watt meter, and check the actual draw of each item individually, in real world usage -- the numbers on the plates are max, and usually never reached.

I run 3 amplifiers in the man cave, along with a powered sub, SACD player, computer, PS3, projector and some minor lighting. I never top 700 watts actual usage. If I pushed it all to the max, I might peak 1400 watts -- which is maybe 12-13 amps draw...

If you take the time to size your system piece by piece, you'll know what actual power requirements you need...
 
Each one of those Conditioners have a Power rating in AMPS. Add the total individual load of the gear you want to use and as long as it does not exceed to power rating of the Furman you should be OK

Where would I look to find it on the gear?
 
Good amps should not have a problem running directly from the wall. I would just run the CD players, mixer, processing, etc. from the Furman and the amps from the wall.

I've been able to run 2 RMX 2450's from a single 15 AMP circuit. However when you push them hard they may need more power than what's available so I just made my circuits 20 AMPS to be on the safe side.

In the past I have been plugging amps to the wall. But now that I'm getting more gear its harder to find outlets close by without running several extention cords. In addition, I also use lights that also need outlets--so I would like to use only one plug for the gear and save the other outlets for the lights that I use.
 
Get a Kill-a-Watt meter, and check the actual draw of each item individually, in real world usage -- the numbers on the plates are max, and usually never reached.

I run 3 amplifiers in the man cave, along with a powered sub, SACD player, computer, PS3, projector and some minor lighting. I never top 700 watts actual usage. If I pushed it all to the max, I might peak 1400 watts -- which is maybe 12-13 amps draw...

If you take the time to size your system piece by piece, you'll know what actual power requirements you need...

What do I look for when sizing up my system? Most of the time I have the dealer tell me what I need. Sometimes that is not the best method--that is why I'm asking & checking if its doable.
 
In the past I have been plugging amps to the wall. But now that I'm getting more gear its harder to find outlets close by without running several extention cords. In addition, I also use lights that also need outlets--so I would like to use only one plug for the gear and save the other outlets for the lights that I use.

2 Words:
Power Distro ;)
 
Doc Jacob's right; you don't need to power your amps through a conditioner. They can be run directly from the AC mains. Use the Furman for frontend gear and processing.

We use a custom extension cord to feed the whole rig. It has a 1900 or 4X4 electrical box with a pair of duplex receptacles. The Furman is plugged into one receptacle, the amps run off another through a heavy duty power strip.
 
An answer to the OP: Look at the power labels usually located next to the AC input of your devices. Add the wattages ( call 100 watts 1 amp for ease) / or amperages together. Add 25% to the total for safety. Now look at the max load on the power label of the conditioner. If your total is less than the rating on the conditioner, you're good to go.

Remember, not ALL of your equipment has to be plugged into the conditioner ( lights or fans, for instance), which could lighten your load.
 
Doc Jacob's right; you don't need to power your amps through a conditioner. They can be run directly from the AC mains. Use the Furman for frontend gear and processing.

We use a custom extension cord to feed the whole rig. It has a 1900 or 4X4 electrical box with a pair of duplex receptacles. The Furman is plugged into one receptacle, the amps run off another through a heavy duty power strip.

Got it, I will use a HD power strip for the amps and everything else on the furman.
 
An answer to the OP: Look at the power labels usually located next to the AC input of your devices. Add the wattages ( call 100 watts 1 amp for ease) / or amperages together. Add 25% to the total for safety. Now look at the max load on the power label of the conditioner. If your total is less than the rating on the conditioner, you're good to go.

Remember, not ALL of your equipment has to be plugged into the conditioner ( lights or fans, for instance), which could lighten your load.

The power conditioner has a rating of 1800 Watts--now I will need to check my labels on all of my gear and add things up--thanks for the explanation!
 
Doc Jacob's right; you don't need to power your amps through a conditioner.

I take it you've never gigged in a building with 100 volts (or less)? I smoked a pair of powered speakers, year before last, at one. I've got a Furman power regulator and pretty much everything gets run off it now (small rig).
 
I take it you've never gigged in a building with 100 volts (or less)? I smoked a pair of powered speakers, year before last, at one. I've got a Furman power regulator and pretty much everything gets run off it now (small rig).

Before plugging in anywhere one should check the outlets and voltage at said outlets. I would consider doing this before setting things up will let you prevent headaches and that's why there are other things to use to protect your gear.
 
I take it you've never gigged in a building with 100 volts (or less)? I smoked a pair of powered speakers, year before last, at one. I've got a Furman power regulator and pretty much everything gets run off it now (small rig).

My house runs between about 89 and 130 volts -- depends on whether they're unloading an oil barge across the street, or one of the huge compressors comes on. My stuff just ceases working when the voltage goes too low -- never trashed anything...

The power supply should be able to handle it.

Most so called voltage regulators, do not actually regulate voltage -- they simply shut down power if the upper or lower limit is exceeded. That's why if yer anal, you need a power re-generator. It converts to DC, filters, then back to AC at a specific voltage and frequency.

They aren't cheap -- couple grand will get you a decent one... ;)


Before plugging in anywhere one should check the outlets and voltage at said outlets. I would consider doing this before setting things up will let you prevent headaches and that's why there are other things to use to protect your gear.

I agree -- yet another reason to have a Kill-A-Watt meter. Just plug it in, and read the voltage, freq., etc. :)
 
I take it you've never gigged in a building with 100 volts (or less)? I smoked a pair of powered speakers, year before last, at one. I've got a Furman power regulator and pretty much everything gets run off it now (small rig).

Actually, I have. More times than I care to recall during my tenure in this crazy biz.

Have seen my share of shoddy electrical service in venues... converted schoolhouses, old rental places out in the sticks with ancient electrical services. Played in back yards, fed from an old receptacle in the garage that was shared with the well pump. I've watched the voltmeter drop to around 90 and the festoon lighting dim when the bass hit.

Being at the end of a long, cheap-assed extension cord ain't no picnic either. :eek:

We don't own active cabinets. Never have, never will. Amps are old-school Toroid A/B with big honkin' DC supplies. They'll take a beating from the AC line and keep on going. If it gets too bad they'll go into self-protect. They don't need to be fed through a conditioner. :)
 
...
Most so called voltage regulators, do not actually regulate voltage -- they simply shut down power if the upper or lower limit is exceeded. That's why if yer anal, you need a power re-generator. It converts to DC, filters, then back to AC at a specific voltage and frequency.

They aren't cheap -- couple grand will get you a decent one... ;)

My power conditioner is custom built- by me. Rick's right about the re-generator, but if you build it yourself, it's under $100. Of course if you're going to do the whole thing right, toss in frequency regulation as well.

I'm betting that the conditioner I built is probably available factory made for the medical or aerospace industries, but I haven't found it yet. It sure as heck isn't going to be at the local Guitar Center though....
 
I take it you've never gigged in a building with 100 volts (or less)? I smoked a pair of powered speakers, year before last, at one. I've got a Furman power regulator and pretty much everything gets run off it now (small rig).

I do mostly school dances and I'm sure that thier buildings are rated at or above 100 volts.