To much Power

To many ads? Support ODJT and see no ads!

bizzyb53

DJ Extraordinaire
Jul 20, 2008
455
62
68
Pittsburgh,Pa.
I have played this gig 2 times.the first time I plugged my furman power conditioner into the wall and popped a fuse in the bbe,noticed the power was running at 140,one light below the red lights.The second time I set up,I noticed the same thing but didn't pop a fuse,running at 140 again.Does anybody what the problem could be?Is there any way to bring that wall power down? Talked to other guys that play there said they didn't have a problem. Thanks
 
THere is no way to change the voltage at your end just keep yourself protected. Check the voltage with a proper voltage meter your conditioner readings could be off.
 
THere is no way to change the voltage at your end just keep yourself protected. Check the voltage with a proper voltage meter your conditioner readings could be off.
I plug all my stuff into the power conditioner,Always have,I'm just puzzled.
 
I have played this gig 2 times.the first time I plugged my furman power conditioner into the wall and popped a fuse in the bbe,noticed the power was running at 140,one light below the red lights.The second time I set up,I noticed the same thing but didn't pop a fuse,running at 140 again.Does anybody what the problem could be?Is there any way to bring that wall power down? Talked to other guys that play there said they didn't have a problem. Thanks

I believe you need a voltage regulator, not a conditioner. Here's what I use (although you may need more than 10 amps):

http://www.provantage.com/apc-le1200~7AMPS01Q.htm

This raises voltage on a low-voltage condition and reduces voltage where an over-voltage is happening.
 
A bank of 100 watt light bulbs set up in series before your equipment will lower the voltage, getting the proper amount of drop is the problem with this type of reduction system, but it is cheap!

The real problem is with the power companies transformer or you are on three phase power!
 
1. Double check the wiring on the plug to see what's up.

2. Double check the reading with a DVM.

If the voltage is REALLY that high... there is a SERIOUS problem there and my guess is what Thunder said - you're not on standard 120VAC power - you're on a leg of 3 phase - or you have a floating ground/neutral of some kind (or something similar) causing issues.
 
1. Double check the wiring on the plug to see what's up.

2. Double check the reading with a DVM.

If the voltage is REALLY that high... there is a SERIOUS problem there and my guess is what Thunder said - you're not on standard 120VAC power - you're on a leg of 3 phase - or you have a floating ground/neutral of some kind (or something similar) causing issues.

I did check the outlet with one of those plugs to see if it was wired properly,
and it checked out alright.Thanks
 
A bank of 100 watt light bulbs set up in series before your equipment will lower the voltage, getting the proper amount of drop is the problem with this type of reduction system, but it is cheap!

The real problem is with the power companies transformer or you are on three phase power!

That's what it sounded like to me also that he might be on the "wild leg".

It could be harmonics causing the voltage meter in the furman to read off.

Or the utility could have the transformer just tapped to high.

I have seen it run as high as 135 volts and be considered normal.