Current Draw for Gear/lights

To many ads? Support ODJT and see no ads!
Depends... b/c it can have a variety of different connections made to it the easiest way is to have several premade "tails" so that you can connect to what you find at the venue. Or... you can have a tail permanently made, but then be limited to a specific type of connection (220V 50A probably).

It is VERY easy to hook up though... just 5 lugs inside: Hot 1, 2, 3, Neutral and Ground.

Ben
 
Depends... b/c it can have a variety of different connections made to it the easiest way is to have several premade "tails" so that you can connect to what you find at the venue. Or... you can have a tail permanently made, but then be limited to a specific type of connection (220V 50A probably).

It is VERY easy to hook up though... just 5 lugs inside: Hot 1, 2, 3, Neutral and Ground.

Ben

Oh Lord,

Ben when I hear that sort of thing I think cut the red wire? blue? kaBOOM!

The more I type the more you'll know how little I know about this stuff, unfortunately.

The 220V is like a regular dryer cord right? That sort of outlet? So if I had me a pre-made tail, I would just plug that bad boy into the 220V outlet at the circuit box, and have me 50 amps pumped into my ACD-100?
 
The voltage+socket at one venue might be different than the next. You would want to make some pigtail adapter cables (which can get a little spendy) so that you would have several socket types to choose from.

I do have one request though: If someone could post the different available 220v socket types (pictures) that would be awesome. I've seen several different ones, including a smaller one that looked similar to a 20A household/commercial outlet.
 
I'm on it. :) If I can't find pics, I'll make some line drawings. They're pretty basic.

Ben

I do have one request though: If someone could post the different available 220v socket types (pictures) that would be awesome. I've seen several different ones, including a smaller one that looked similar to a 20A household/commercial outlet.
 
965_sm.jpg
120V 15Amp

966_sm.jpg
120V 20Amp

969_sm.jpg
220V 15Amp

971_sm.jpg
220V 20Amp

972_sm.jpg
220V 30Amp

976_sm.jpg
277V 30Amp

977_sm.jpg
277V 50Amp

992_sm.jpg
220V 60Amp

1027_sm.jpg
This is typical of what you will find in a 3 phase connection, although there are LOTS of different types of connections available.

I would stick to (and they are more common) 120V or 220V connections for simplicity sake. These are typical of what you will find at most venues without having to contact an electrician prior to the event. For schools, and other venues where you may be drawing large amounts of power, you can end a “tech rider” in advance advising THEM of the connectivity that YOU need. Then they can have an electrician make the necessary connections for the tail(s) that you commonly have, rather than you having to have all the possible connections.

Ben

PS – Props to Jim, our Technical Services Mgr at FX for digging these pics up for me. :sqcool:
 
I knew a lot of those already (I'm a CETa) but it sure is nice having them on paper!

I'm wondering how the attached picture fits in. It appears to be either 277/60 or a lower-amperage version of the 277/30 that you posted, but it's for our clothes dryer in the house and I'm wondering how that fits in with 277 (since it shouldn't be 277.....?)

Thanks!
 

Attachments

  • whatisthis.jpg
    whatisthis.jpg
    3 KB · Views: 23
And not to be picky.. but the 110 and 220 20A look identical... are they sized different? :sqconfused:
 
DOH! Not picky... attentive! That's the wrong image. I looked, and the place I got it from has them listed wrong. ;) They indicated that that is a 6-20R... WRONG. It's a 5-20R... or 110V 20A. I'll draw one and post it shortly.

Kudos to you for catching it!

Ben

And not to be picky.. but the 110 and 220 20A look identical... are they sized different? :sqconfused:
 
You don't want to use any of the assorted 220 volt receptacles that have only 3 prongs. If you try to split those to 2 - 120 volt circuits you are left without a safety ground, and there is NOT a legal method for running a separate ground connection using those. They are intended solely for dedicated 220+ volt usage.

For a distro feed you should use only the outlets that provide 2 or 3 hot legs, plus a neutral and a separate safety ground conductor. These are all 4 or 5 conductor receptacles, and can be safely split to provide multiple 120 volt circuits using a breakered distro such as the ACD-100.
 
Okay...here's my attempt at drawing this bad boy. No comments from the peanut gallery please!

This is a NEMA 6-20R (220V 20A).

6-20R.jpg


Ben
 
Thank you Mike. Excellent point! Sometimes those of us that work with this stuff every day forget to look out for those who don't. Good heads up!

Ben

You don't want to use any of the assorted 220 volt receptacles that have only 3 prongs. If you try to split those to 2 - 120 volt circuits you are left without a safety ground, and there is NOT a legal method for running a separate ground connection using those. They are intended solely for dedicated 220+ volt usage.

For a distro feed you should use only the outlets that provide 2 or 3 hot legs, plus a neutral and a separate safety ground conductor. These are all 4 or 5 conductor receptacles, and can be safely split to provide multiple 120 volt circuits using a breakered distro such as the ACD-100.
 
I'm on it. :) If I can't find pics, I'll make some line drawings. They're pretty basic.

Ben

Ben (and others)

Perhaps this will help give you a better idea of what types of connections we are talking about here. These pictures are also available in the Photo Gallery under the "220 Distro Box Pictures" thread.

Hope this helps.
 

Attachments

  • 4 blade adapter.jpg
    4 blade adapter.jpg
    13.4 KB · Views: 2
  • pigtail connector with 3 blade adapter end.jpg
    pigtail connector with 3 blade adapter end.jpg
    15.6 KB · Views: 3
  • custom distro panel full shot.jpg
    custom distro panel full shot.jpg
    15.6 KB · Views: 2
Now I am confused. I know what you mean about the 1-hot vs. 2-hot, but now I see a 2+ground socket adapter in there... what's that for?

What plug do you actually have on the end of the long leader, the 3+ground? And what is the 2+ground w/bare wire adapter for?

This thread is getting long but I'm just trying to not only make sense of what I don't understand, but what people who know nothing about wiring must be wondering also :)

[I'm editing my post already because I see that there's 4 color conductors on that 3 prong socket.... how's that work? Is the center a ground or something (thought that was just a screw?)]
 
Everyone reading this material must realize this information is provided as background material only and not as a “how to”. Electrical power can be very dangerous if you are not fully familiar with the NEC (electrical code) and how to safely use and connect the circuits. Always check in with the house electrician before using an unfamiliar circuit. DON’T HOOK THIS STUFF UP UNLESS YOU ARE FULLY FAMILIAR WITH WHAT YOU ARE DOING. IF YOU HAVE ANY DOUBT, GET A LICENSED ELECTRICIAN.

Sorry ‘bout that guys, it is my job to make sure everyone stays safe.

The typical colors are:

Single phase 110VAC
Black (hot)
White (neutral)
Green (ground)

Full Edison Circuit
Black (leg one)*
Black or Red (leg two)*
White (neutral) - wire not needed if circuit only needs 220VAC
Green (ground)

Three phase (typical) - Voltages depend upon connections
Black (L1 hot)
Red (L2 hot)
Blue (L3 hot)
White (neutral) - may or not be present, depends upon circumstance.
Green (ground)

*Connecting from one hot leg to another provides 220VAC while connection from one hot leg to neutral provides 110VAC.
 
AMEN!

Ben

Everyone reading this material must realize this information is provided as background material only and not as a “how to”. Electrical power can be very dangerous if you are not fully familiar with the NEC (electrical code) and how to safely use and connect the circuits. Always check in with the house electrician before using an unfamiliar circuit. DON’T HOOK THIS STUFF UP UNLESS YOU ARE FULLY FAMILIAR WITH WHAT YOU ARE DOING. IF YOU HAVE ANY DOUBT, GET A LICENSED ELECTRICIAN.