Line noise? ground problem? help! can't figure it out

To many ads? Support ODJT and see no ads!
Fred was right I had the same problem with my JBL's. I solved it with his help by looking back in the chain. Before anything was connected to speakers, hum started as soon as power was turned on.But when I had everything ...speakers, mixer, crossover, CD Players plugged directly into my Furman, and the Furman into one outlet, hum gone. Prior to the problem I would plug the speakers into strips, and into separate outlets. It requires having some longer A/C cords, but problem is solved.I even plugged the strips into the Furman, but I still had the Buzz?
 
Thanks, Brother Jim. :)

Electrical systems in venues cannot be guaranteed to be up to code. For our part, all we can do is ensure that our equipment works well the way we've found it to work at home during trials.

And don't connect up to anyone's GFCI circuit, trust me on this one. :D

If a venue's electrical service is garbage (and many are) it's not our fault. But we must determine the integrity of our equipment first. The point is to bring a professional system to the show. If the venue cannot supply a professionally installed branch circuit, that's on them. We've done our part.

If it comes to that, keep a Honda genny in the truck just in case. :)
 
Do you carry The Generator with you on your Gigs? Or do you leave and pick it up when you need it.........What do they cost new? How big do you need, normal set-up 2 Tops, Sub and rig..........
 
why? I know what it stands for, will it trip if there is an inrush of juice?

just curious....thanks for sharing...
They won't trip on an inrush if they're installed and wired correctly. That's a big "if". I've connected our rig to a GFCI outside and it tripped as soon as the amps were powered up. Ran a cord to another GFCI in the garage at the same house and rocked the party all night.

In my experience, GFCI receptacles can be come weak and, often useless over time. Line voltage spikes from electrical storms are notorious for this. Also, outdoor receptacles are subject to deterioration due to exposure to the elements.

And again, you're at the mercy of the person who installed it. These things have a hair trigger... and if the ground or neutral bonds are slightly weak, they'll trip. When I was doing outdoor installs I always used Noalox on the GFCI bonding screws. I didn't want to have to go back and do the job over later.

Doing the install right the first time often isn't a priority for helpers. And helpers do much of the install work.

I rest my case. :)