In this case, I'd suggest setting up as close to the house as you can. If you're gonna be set up in a tent, this may be a stretch. Please ensure that you'll have at least two dedicated 20 amp outlets available to you.
I'd suggest splitting the power amp load between the circuits with the frontend equipment shared with the highs/mid amps. The lows amps should be fed with their own AC circuit. Just a reminder ~ you don't need to run power amps through conditioners.
Get a measurement of the distance you'll be running your power. Take into account the extra distance with twists and turns... going around the deck, for example. It's never as the crow flies. Get no smaller than 12 gauge AC cords for your runs.
Do
not depend upon the client to provide these... they always say they will but they never do. Leave it to them and you may end up at the end of a pipsqueak AC cord that's better suited for running a hedge trimmer. And they've got the tent festoon lighting on the same damn circuit. We have seen this.
Find the outlets you'll need, make a note of where they are and tell the client that you (and you alone) will be using them for the duration of the engagement. They are not to be used for anything else during the show, that's final. No coffee makers, no freezers, no fridge, no festoon lighting, no nothing. And do not let anyone wheedle you into sharing with catering etc. They can find their own power.
Then obtain 12 gauge extension power cords that will be long enough to get to the tent area. These can be got at Lowes or Home Depot. Ensure that they are 12 gauge before you buy them. The wire gauge is printed on the cable jacket.
I apologize for the long post but I wanted to help you avoid some of the pitfalls we've dealt with at outdoor shows over the years. Bring everything you will need to the show. Please don't take someone else's word that what you need will be there. It rarely is.
The reason I say all this ~ if you are at the end of a pipsqueak cord your bass thump will dim the lighting and quite possibly kill the power altogether. You don't need the headaches. Ensure that you'll have a couple of 20 amp branch circuits dedicated for your use.
Hope it helps.